Case Study · 01
Persistent cervical and radicular pain after multilevel anterior and posterior fusion
A 68-year-old woman with persistent neuropathic cervical pain and upper-extremity radicular symptoms after multilevel anterior cervical discectomy and fusion followed by posterior cervical fusion with instrumentation. Postoperative fibrosis and postsurgical changes contributed to an ongoing pain pattern despite prior treatment. An Abbott cervical spinal cord stimulator trial reduced the original symptom burden by approximately 85%, followed by permanent implantation with paired epidural leads extending to the C2 vertebral level. More than five years later, benefit remains approximately 85–90% with periodic programming optimisation.
At a glance
- Patient
- 68-year-old woman
- Region
- Cervical and upper extremities
- Procedure
- Abbott cervical SCS, lead tips at C2
- Outcome
- 85–90% relief sustained beyond 5 years
When extensive cervical reconstruction is structurally complete but neuropathic neck and arm pain persists, can a cervical spinal cord stimulator provide durable relief without another reconstructive operation?
Patient names are omitted from this account. The clinical course and reported outcome describe an actual treated case and do not predict another person's response.
Clinical Summary
What the patient came in with
Presentation
Persistent cervical pain with burning, electric and radiating symptoms into the upper extremities following extensive cervical surgery. The neuropathic and radicular features limited sleep, sustained neck positioning, household activity and use of the arms for prolonged tasks.
Symptoms continued after the expected postoperative recovery period and had become a chronic postsurgical pain condition rather than a short-term consequence of healing.
Surgical history and pain generator
The patient had undergone multilevel anterior cervical discectomy and fusion with anterior hardware, followed by posterior cervical fusion with additional instrumentation. The reconstruction left both anterior and posterior surgical changes across multiple cervical levels.
Ongoing symptoms were associated with postoperative fibrosis, scar tissue and altered neural tissues surrounding the previously operated levels. The clinical pattern remained neuropathic and radicular, without a straightforward additional operation expected to resolve it.
Why cervical spinal cord stimulation
The treatment objective was to modulate persistent cervical and upper-extremity neuropathic signaling rather than revise a structurally completed fusion. A temporary stimulation trial allowed the patient to evaluate the therapy during ordinary daily activity before considering a permanent implant.
An Abbott spinal cord stimulation system was selected for the cervical trial. The lead plan was designed to create coverage across the neck and upper-extremity symptom distribution while maintaining flexibility for future programming as the pain pattern evolved.
Pre-implant evaluation
The prior operative history, current imaging, neurological examination and treatment record were reviewed before proceeding. The patient completed the standard psychosocial evaluation and received detailed counselling regarding realistic goals, activity restrictions, hardware risks and the need for long-term device follow-up.
Success was defined before the trial as meaningful reduction in the original cervical and radicular symptoms together with measurable improvement in sleep and daily activity—not simply a favourable pain score recorded in the procedure area.
Procedure
Paired cervical epidural leads extending to C2
The temporary trial and permanent implant used conventional spinal cord stimulator leads within the cervical epidural space. The rostral lead contacts were positioned at approximately the level of the C2 vertebral body to address the cervical and upper-extremity neuropathic pain distribution.
Procedural Imaging
Position confirmed in two fluoroscopic planes
AP and lateral fluoroscopy document the paired high-cervical lead configuration in relation to the patient's prior anterior and posterior fusion constructs.
Paired leads centered at the C2 levelThe paired epidural leads course near the cervical midline, with the rostral contacts positioned at approximately the C2 vertebral-body level. The pre-existing fusion instrumentation is also visible. Posterior epidural position confirmedThe lateral projection confirms that the leads lie posteriorly within the cervical epidural space, again terminating at approximately the C2 vertebral-body level.
01
AP fluoroscopic view
Epidural access
Percutaneous epidural access was obtained below the intended stimulation field, allowing the trial leads to be advanced cranially through the cervical epidural space under continuous fluoroscopic guidance.
02
AP and lateral views
First lead advanced to C2
The first lead was advanced until its tip reached approximately the C2 vertebral-body level. Orthogonal imaging confirmed a dorsal epidural position and the intended high-cervical trajectory.
03
Cervical epidural space
Paired lead placement
A second lead was positioned alongside the first to create a balanced stimulation field across the cervical region and upper-extremity pain territories. The paired configuration also provided options for later programming refinement.
04
Temporary external system
Cervical SCS trial
During the trial, the patient tracked the same neck and arm symptoms that had limited function before the procedure. The original symptom burden decreased by approximately 85%, with corresponding improvement in daily activity and sleep tolerance.
05
Following successful trial
Permanent Abbott implant
After the successful trial, permanent cervical epidural leads were placed with their tips again near C2 and connected to the implanted Abbott pulse generator. Final imaging documented lead position before completion of the procedure.
Follow-Up
What happened afterwards
The trial period
The patient reported approximately 85% reduction in the previously described cervical neuropathic pain and upper-extremity radicular symptoms. Functional improvement was consistent enough throughout the trial to support permanent implantation.
The magnitude and distribution of relief matched the goals established before the trial rather than reflecting improvement in only one isolated symptom.
After permanent implantation
Following healing and initial programming, relief stabilised in the 85–90% range. The patient reported durable improvement in the cervical and upper-extremity symptoms that had driven the original treatment decision.
Programming was adjusted as needed to maintain comfortable coverage and respond to changes in activity and symptom distribution.
More than five years
The patient has continued periodic follow-up for stimulator assessment, adjustment and programming optimisation for more than five years since implantation.
Relief remains approximately 85–90% compared with the pre-procedure symptom burden. The sustained response illustrates that long-term success includes ongoing clinical follow-up rather than a one-time implant followed by no further care.
Outcome
Durable relief maintained beyond five years
85–90%
Reduction in the original symptom burden
- Trial response
- Approximately 85%
- Lead location
- Cervical epidural space to C2
- Follow-up
- More than 5 years
- Long-term care
- Periodic programming optimisation
Clinical pearl
A successful spinal cord stimulator implant is not a static event. Careful trial selection established that the target was correct; durable relief over more than five years has depended on preserving the lead strategy and periodically refining the programming as the patient's needs changed.
Individual results vary. This case is presented for education and does not predict the outcome of any therapy in any other patient.
Put this case in context
Individual outcomes cannot predict yours. Learn how candidacy is assessed, or explore U.S. physician listings as an unverified starting point for finding care. This site does not book appointments.